About Selecting Temperature Sensors
More
Quick-Connect Thermocouple Probes for Surfaces
The probe tips come attached to mounting connections for fast installation.
Note: When installing probes with wire leads, the red wire is negative.
Bolt-on probes mount on motors, machines, and other equipment for temperature readings in high-vibration environments.
Material | Wire | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Thermocouple Type | Temperature Range, ° F | Probe Lg. | Accuracy | Response Time, sec. | Connection Type | Sensor Type | Insulation | Jacket | Lead Lg. | Gauge | Wd. | Thick. | Bolt Hole Dia. | Fasteners Included | Each | |
Nickel Probe | ||||||||||||||||
J | 32° to 900° | 5/8" | ±0.75% | 2 | Wire Leads | Grounded | Fiberglass | 300 Series Stainless Steel | 48" | 24 | 5/16" | 1/16" | 3/16" | No | 0000000 | 000000 |
K | 32° to 900° | 5/8" | ±0.75% | 2 | Wire Leads | Grounded | Fiberglass | 300 Series Stainless Steel | 48" | 24 | 5/16" | 1/16" | 3/16" | No | 0000000 | 00000 |
T | 32° to 900° | 5/8" | ±0.75% | 2 | Wire Leads | Grounded | Fiberglass | 300 Series Stainless Steel | 48" | 24 | 5/16" | 1/16" | 3/16" | No | 0000000 | 00000 |
Quick-Connect RTD Probes for Surfaces
For fast installation, the tips of these RTD probes come attached to mounting connections.
Bolt-on probes securely mount on machines, motors, and other equipment.
Probes with a wire ferrule protect stranded wire and aid installation into screw terminals on controllers and data loggers.
Probes that meet DIN EN 60751 adhere to industry standards for accuracy. Those that meet MS-202 (Method 204, Test Condition D) are for use in high-vibration environments. IP67 rated probes protect against dust and temporary submersion.
Probe | Wire Lead | Thread | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temperature Range, ° F | Lg. | Wd. | Thick. | Accuracy | Response Time, sec. | Jacket Material | Lg. | Gauge | No. of Wires | Wire Color | Size | Pitch, mm | Bolt Hole Dia. | Environmental Rating | Specifications Met | Fasteners Included | Each | ||
Micro M12 Plug Connection—Stainless Steel Probe | ||||||||||||||||||||
C | 100 ohms | -40° to 190° | 15/16" | 5/16" | 3/16" | ±0.5% | 8 | Polyurethane | __ | 22 | 4 | Brown/Blue/Black/White | M5 | 0.8 | __ | IP67 | DIN EN 60751 Class A | __ | 0000000 | 0000000 |
C | 100 ohms | -40° to 190° | 15/16" | 5/16" | 3/16" | ±0.5% | 9 | Polyurethane | __ | 22 | 4 | Brown/Blue/Black/White | M6 | 1 | __ | IP67 | DIN EN 60751 Class A | __ | 0000000 | 000000 |
C | 100 ohms | -40° to 190° | 2" | 7/16" | 5/16" | ±0.5% | 15 | Polyurethane | __ | 22 | 4 | Brown/Blue/Black/White | __ | __ | 1/2" | IP67 | DIN EN 60751 Class A | __ | 0000000 | 000000 |
C | 100 ohms | -20° to 350° | 15/16" | 5/16" | 3/16" | ±0.5% | 8 | Silicone | __ | 22 | 4 | Brown/Blue/Black/White | M5 | 0.8 | __ | IP67 | DIN EN 60751 Class A | __ | 0000000 | 000000 |
C | 100 ohms | -20° to 350° | 15/16" | 5/16" | 3/16" | ±0.5% | 8 | Silicone | __ | 22 | 4 | Brown/Blue/Black/White | M6 | 1 | __ | IP67 | DIN EN 60751 Class A | __ | 0000000 | 000000 |
Wire Ferrule Connection—Stainless Steel Probe | ||||||||||||||||||||
D | 100 ohms | -20° to 300° | 1 3/16" | 3/8" | 11/16" | ±0.5% | 12 | Silicone | 40" | 22 | 4 | Red/White | M12 | 1.5 | __ | IP67 | DIN EN 60751 Class A | __ | 0000000 | 000000 |
E | 100 ohms | -10° to 190° | 1 13/16" | 7/16" | 5/16" | ±0.5% | 39 | Polyurethane | 40" | 22 | 4 | Brown/Blue/Black/White | __ | __ | 1/4" | IP67 | DIN EN 60751 Class A | __ | 0000000 | 00000 |
Wire Leads Connection—303 Stainless Steel Probe | ||||||||||||||||||||
F | 100 ohms | -55° to 500° | 3/8" | __ | __ | ±0.12% | 10 | PTFE | 40" | 26 | 3 | Red/White | 1/4"-20 | __ | __ | __ | DIN EN 60751 Class B; MS202 (Method 204, Test Condition D) | Yes | 0000000 | 000000 |
F | 1,000 ohms | -55° to 500° | 3/8" | __ | __ | ±0.12% | 10 | PTFE | 40" | 24 | 2 | Red/White | 1/4"-20 | __ | __ | __ | MS202 (Method 204, Test Condition D) | Yes | 0000000 | 000000 |
G | 100 ohms | -55° to 500° | 3/8" | 1/2" | 3/16" | ±0.12% | 10 | PTFE | 40" | 26 | 3 | Red/White | __ | __ | 5/32" | __ | DIN EN 60751 Class B; MS202 (Method 204, Test Condition D) | No | 0000000 | 000000 |
G | 1,000 ohms | -55° to 500° | 3/8" | 1/2" | 3/16" | ±0.12% | 10 | PTFE | 40" | 24 | 2 | Red/White | __ | __ | 5/32" | __ | MS202 (Method 204, Test Condition D) | No | 0000000 | 000000 |
Wire Leads Connection—316/316L Stainless Steel Probe | ||||||||||||||||||||
H | 100 ohms | -90° to 930° | 1 1/4" | 5/16" | 3/16" | ±0.12% | 10 | Mica Glass | 40" | 22 | 3 | Red/White | __ | __ | 5/32" | __ | DIN EN 60751 Class B; MS202 (Method 204, Test Condition D) | No | 0000000 | 000000 |
H | 1,000 ohms | -90° to 930° | 1 1/4" | 5/16" | 3/16" | ±0.12% | 10 | Mica Glass | 40" | 22 | 2 | Red/White | __ | __ | 5/32" | __ | MS202 (Method 204, Test Condition D) | No | 0000000 | 000000 |
Wire Leads Connection—300 Series Stainless Steel Probe | ||||||||||||||||||||
J | 100 ohms | -90° to 930° | 1" | 1/2" | 3/16" | ±0.12% | 10 | Mica Glass | 40" | 22 | 3 | Red/White | __ | __ | 5/32" | __ | DIN EN 60751 Class B; MS202 (Method 204, Test Condition D) | No | 0000000 | 000000 |
J | 1,000 ohms | -90° to 930° | 1" | 1/2" | 3/16" | ±0.12% | 10 | Mica Glass | 40" | 22 | 2 | Red/White | __ | __ | 5/32" | __ | MS202 (Method 204, Test Condition D) | No | 0000000 | 000000 |
Wire Leads Connection—Nickel-Plated Copper Probe | ||||||||||||||||||||
K | 100 ohms | -55° to 500° | 1" | 1/2" | 3/16" | ±0.12% | 10 | PTFE | 40" | 26 | 3 | Red/White | __ | __ | 17/64" | __ | DIN EN 60751 Class B; MS202 (Method 204, Test Condition D) | No | 0000000 | 000000 |
K | 1,000 ohms | -55° to 500° | 1" | 1/2" | 3/16" | ±0.12% | 10 | PTFE | 40" | 24 | 2 | Red/White | __ | __ | 17/64" | __ | MS202 (Method 204, Test Condition D) | No | 0000000 | 000000 |